| Error |
Dominio(Entorno) |
Sintoma
(Visible para el usuario) |
Problemas Técnicos |
Operación que ejecuta CATDUA |
Después de ejecutar
CATDUA (Visible para el usuario) |
| AFI_1 (3) |
Assembly
Design |
Link fantasmas en el
comando SendTo. |
Inconsistencia de la
lista de features a las que apunta la Assembly Feature. |
Borrado de la lista de la feature a la que apunta y reconstrución de la información válida. |
Desaparecen los Links no válidos en el comando del assembly Send/To. |
| AFI_2 (2) (*) |
Assembly
Design |
Some ghost links appear SendTo command. |
An instance of a Reuse Pattern feature was pointing into
a wrong document, probably because of a problem during feature
synchronization. |
Unset the pointing attribute on the instance. |
No more ghost links in Send To command. |
| AFI_3 (3) (*) |
Assembly
Design |
Ghost links
in File/SendTo command from a CATProduct. |
ASSYFEATPATTERN are feature extensions of CONNECTION feature. the whole
product structure was instantiated in a CATWorkSceneProdCont (container
dedicated to the old Scenes), and so was the CONNECTION and its
ASSYFATPATTERN. But the instance->reference link of the ASSYFEATPATTERN
had been corrupted and it was pointed to its Start-Up instead of the
right reference.
Some links of the reference ASSYFEATPATTERN had been modified, but the
instance ASSYFEATPATTERN could not be synchronized and still had links
to unnecessary documents. |
Plug the
instance to the right reference and Reset/Synchronize it |
Ghost links
disappear; from the ASSYFEATPATTERN point of view there is no
consequence because the instance are not seen by the user and aren't
taken into account in the Update process. |
| AGG_1 (1) |
Aggregation |
Aggregated
object does not know its aggregating object. |
Aggregated
object does not know its aggregating object. |
Deletion
of the aggregation. |
None.

|
| AGG_3 (2) |
Aggregation |
Nothing happens when deleting an instance in a product. |
A link Father-Son between an instance and the product is
deleted, which disables the destruction of the instance. |
Use the Spec service CATSpecSetFather to reset the link. |
The instance can be deleted. |
| AGG_4 (1) |
Aggregation |
A constraint
is broken when making a product flexible. Before making the product
flexible there was no problem. The rule UAV_6 applied on documents
instantiating this one detected the problem but did not resolve it. |
In the upper
document, a connector was not known by the Product Instance, so it was
not instantiated in other documents. |
Connector is
set back on the right attribute of the Product, and instantiated on all
referencing documents. |
Constraints
instances pointing at connector instance can retrieve it and are not
broken any more.
User might need to run the Cleaner in the documents that reference this
one: UAV_6 rule might detect a problem and correction has to be made. |
| ASD_0 (1) |
Assembly
Design |
Constraint is
wrong displayed or ignored during update. |
The start up
of constraint is not found. |
Load the
AsmCst.feat catalog. |
Product is
non up-to-date.
Document needs to be updated. |
| ASD_1 (1) |
Assembly
Design |
Constraint is
wrong displayed or ignored during update. |
Unused
Constraint without connection are present (when a connection is deleted
the constraint is not). |
Deletion of
unused constraints. |
Product is
non up-to-date.
Document needs to be updated. |
| ASD_2 (1) |
Assembly
Design |
Constraint is
wrong displayed or ignored during update. |
Constraint is
defined in a wrong container. |
Deletion of
the constraints. |
Product is
non up-to-date.
Document needs to be updated. |
| ASD_3 (2) |
Assembly
Design |
Constraint is not correctly displayed or ignored during
the update. |
The type of a constraint is lost. |
Restore the type of the constraint. |
Constraint is correctly displayed or updated. Document
needs to be updated. |
| ASD_4 (2) |
Assembly
Design |
Constraint is
wrong displayed or ignored during update. |
Bad quality
of constraints attribute. |
Change the
quality of attributes. |
Product is
non up-to-date.
Document needs to be updated.

|
| ASD_5 (1) |
Assembly
Design |
The
FixTogether node in the graph does not appear ; there is a blue
CONNECTION node instead. Such data may cause a coredump at Open or at
Close. This occurs on data containing a Fix Together created in V5R12
GA. |
Inconsistency between the feature catalog in V5R12 GA and the catalog in
later versions or service packs. |
The
corrupted Fix Together is deleted and replaced by a new Fix Together. |
The Fix
Together node appears in the graph, there is no more CONNECTION node ;
if the Fix Together was pointing another Fix Together, this information
is lost. The name is lost too. |
| ASD_6 (1) |
Assembly
Design |
A constraint
can not be created. |
A Fix
Together node without parent (connection). |
the corrupted
Fix Together is deleted. |
The
constraint can be created.
Document needs to be updated. |
| ASD_7 (2) |
Assembly
Design |
Two parts linked with a contact constraint has wrong
orientation. |
An attribute of a constraint contains a wrong value. |
Set the right value to the attribute of the constraint. |
The contact constraint is out of date. Document needs
to be updated |
| ASD_8 (3) |
Assembly
Design |
Activity of
the FixTogether is not displayed in F(x). |
Activity
parameter of the FixTogether is not valuated. |
Valuate the
Activity parameter of the FixTogether. |
FixTogether is displayed in F(x).
|
| ASD_9 (3) |
Assembly
Design |
Impossible to reorder constraints or set of constraints in Assembly
Design. |
Some old sets, existing in no more existing component, still present
in the document, disrupt the management of set and constraints. |
Delete of those old and not used set of constraints. |
It is
possible to reorder constraints or Set of constraints. |
| ASD_10 (2) |
Assembly
Design |
Some
constraints can be seen in the 3D window, but they do not appear in the
specifications tree. When the user adds another constraint, lots of
constraints appear in the specification tree, they disappear if the user
deletes the new constraint. |
Aggregation problem: the CONNECTION does not know the ConstraintASM,
but the ConstraintASM knows that the CONNECTION is its parent. |
ChangeFather of the ConstraintASM and reconnect it properly to the
CONNECTION. |
If CATDUA is launched in a CATIA session, the user will need to
refresh the specification tree to see the constraints (e.g. launch
command 'Window/New Windows, or Save and Reopen the CATProduct). CATProduct needs to be updated. |
| ATT_2 (3) |
Product
Structure |
No visibility
(can appear when an assembly update fails). |
Internal (and
unnecessary) attribute incorrectly valuated. |
Unset the
value of this attribute. |
No
visibility. |
| ATT_3 (1) |
Product
Structure |
Send To
command shows a link to a CGR in V5Cache (concern only V5R1
CATProducts). |
Internal (and
unnecessary ) attribute incorrectly valuated. |
Deletion of
unnecessary link. |
El comando Send To
no muestra estos link. |
| ATT_4 (2) |
Product
Structure |
The result of
an update (in terms of position) is not correct even if no error is
reported. |
Internal
value to determine whether an update (in position) is needed is
incorrectly valuated. |
Set the
internal attribute to the correct value. |
Document
needs to be updated. After the update the part is correctly
positioned. |
| BDR_0 (3) |
PlantShip
Modeler |
The user
will be prompt with error window if an old version of 2D/3D modeling
exist. |
New 2D/3D
modeling would eliminate the dependency of schematic documents, reduce
data size, support ENOVIA LCA revision and configuration. |
Upgrade
existing, 2D/3D modeling without direct pointing to schematic/fake
functions. |
No more
error window and reduced model size. |
| BOL_0 (2) |
Part Design |
Visualization problems due to Boolean between Solid body (old) and
hybrid body (new). |
Boolean
operation between solid body (old) and hybrid body (new). |
The operand
body is moved under the part. |
Specification tree changes since operand body is moved from under
boolean to under part. |
| BRK_0 (1) (*) |
Product
Structure |
Ghost link.
CATIA announces that a document can not be retrieved, and the link does
not appears in Edit/Links or File/Desk. |
Object owner
of the link is not aggregated and CATIA does not find information about
object type. |
In this case
the internal link owner is supposed to be unused. Delete this is
performed on this broken object |
No more Ghost Link in the command.

|
| BST_0 (3) |
PlantShip
Modeler |
A document
created with a previous version can not be loaded |
Without the
declaration of backup startup class, the document cannot be loaded
without the associated CATfct. |
Declare
object's backup startup class. |
The document
can be loaded. |
| BST_1 (3) |
Mechanical
Modeler |
An external
user can not see CAA features created with a previous version. |
When the
startup catalog for CAA features is not present, the features cannot be
displayed. |
Declare
object's backup startup class. |
An external
user can see the CAA features. |
| CAT_0 (2) |
SpecsModeler |
A core-dump
may occur when accessing some data. |
A
CatalogManager does not point a catalog document. |
The pointing
to the document that is not a catalog is removed. |
No more
core-dump when accessing data. |
| CCL_0 (3) |
SpecsModeler |
The
description's name and the "Name" keyword value are different. |
The
description's name is wrong. |
The
description's name is set with the "Name" keyword value. |
The
description is renamed. |
| CCL_1 (3) |
SpecsModeler |
The same
chapter appears with a name in the Specifications tree and with another
name in the definition list. |
The chapter's
name is wrong. |
The chapter's
name is set with the name that appears in the definition list. |
The chapter
is renamed. |
| CCL_2 (3) (*) |
SpecsModeler |
Some ghost links appear in the SendTo or Save in Enovia
commands. |
When a chapter's keyword is deleted, some internal data
associated with the chapter's keyword are not deleted and remain in
descriptions. |
Useless internal data are now removed. |
No more ghost links in Send To command and in Save
in Enovia. |
| CCL_4 (3) |
SpecsModeler |
A description's keyword value may be unlinked with its
chapter's keyword in rare cases (CAA). An unlinked keyword value is not
removed if its keyword is removed. |
Removing a keyword may create ghost links if its keywords
values are unlinked. |
The keyword value is re-linked with its keyword. |
Removing a keyword will remove its keywords values. |
| CCL_5 (2) |
SpecsModeler |
Chapters
cannot be viewed in the catalog Editor despite they are found by
batch. |
No descriptions are pointing to the chapter, so it is not taken into
account in the viewer. |
Create a new description under the root chapter that points to the
chapter. |
Chapters are
correctly displayed in the tree of the catalog Editor. |
| CDC_0 (1) |
PlantShip
Modeler |
The user will
be prompt with error window if an invalid version of cross document
connections exists. |
Publication
based on cross document connection would support ENOVIA LCA revision and
configuration. |
Use
publication to support cross document connections. |
No more error window.

|
| CPF_0 (3) |
Part Design |
Size of a CATPart is abnormally huge comparatively to the number of
elements. |
Unreferenced
BREP features in the Part design Feature. |
Delete the Unreferenced BREP features. |
Reduce el tamaño del modelo. |
| CRV_0 (2) |
Sketcher
Modeler |
Curves
created outside the Sketcher workbench with no endpoints. |
The resulting
geometry associated to the sketch is not consistent. |
Required
endpoints are added. |
Sketches are
seen as non up-to-date. Document needs to be updated. |
| CRV_1 (3) |
Sketcher
Modeler |
Update result is not right because update propagation is wrong. Some
features are not impacted by geometries modifications. Ex: Output
features. |
Attributes of several features are set to sp_NEUTRAL instead of
sp_IN. |
Set quality
of curves attributes to sp_IN. |
No impact, except when cleaned geometries are published by output
features.
Then Document needs to be updated.
|
| CST_1 (2) |
Sketcher |
Some sketcher
constraints are not usable anymore (always broken). |
Internal
attribute to determine the type of the constraint is not valuated. |
Set the
internal attribute to the correct value. |
Document
needs to be updated. The constraint can be used again. |
| CST_2 (2) |
Sketcher |
CPU loop or
problem with activation/deactivation of a constraint. |
Bad quality
of constraints attribute. |
Change the
quality of attribute. |
Document
needs to be updated. The constraint can be used again. |
| CST_3 (1) |
Sketcher |
Some sketcher
constraints are wrong displayed or ignored during update. |
Value of a
constraints attribute is lost. |
Deletion of
the constraint. |
Document
needs to be updated. The constraint can be used again. |
| CST_4 (2) (*) |
Sketcher |
Ghostlink on
a CATDrawing in SendTo command. |
Ghost Link on
a CATDrawing document due to an invalid "blocs" attribute of a
constraint. |
Valuate the
"blocs" attributes of the constraint. |
No more Ghost
link in Send To command. Document needs to be updated. |
| CTX_1 (3) (*) |
Mechanical
Modeler |
Part is
contextual to several products, which is not supported by several tools
(Edit Links, Define Contextual Links, etc). |
Part is
contextual to several products, which is not supported by several tools
(Edit Links, Define Contextual Links, etc). |
Deletion of
all contexts except first one. |
Some external
references may be isolated. |
| DAC_0 (1) (*) |
Drafting |
Ghost link on
another document from annotation. |
The leader of
the annotation belongs to another document. |
Delete the
annotation and its leader. |
No more
annotation, no more ghost Link. |
| DAC_1 (1) |
Drafting |
The number of
graphical dimensions found by search command is higher than the number
of graphical dimensions seen by the user. |
The
representation of the graphical dimension (dimension imported from V4)
cannot be found. |
Deletion of each graphical dimension that is not visualized in the
view. |
Only the visualized graphical dimensions can be found by search
command. |
| DAF_0 (3) |
Drafting |
AreaFill is
an empty space. |
AreaFill not
associated to any geometrical elements. |
Deletion of
the AreaFill. |
AreaFill has
disappeared. |
| DAF_1 (3) (*) |
Drafting |
An AreaFill
can not be selected. |
AreaFill non
aggregated. |
Deletion of
the AreaFill. |
AreaFill has
disappeared. |
| DAF_2 (3) (*) |
Drafting |
An AreaFill
disappears when updating the view. |
AreaFill with
a missing curve. |
Deletion of
the AreaFill. |
AreaFill has
disappeared. |
| DAF_3 (3) |
Drafting |
The drawing
contains some AreaFills that the user can not see (only by using the
Search function). |
Areafill
without pattern. |
Deletion of
the AreaFill. |
AreaFill has
disappeared. |
| DAF_4 (1) |
Drafting |
A document
contains Area Fills with ghost links to other documents. Ghost link is
visible in SendTo command. |
Some Area Fill points other drawing after copy/ paste from a document
to another. |
Delete these
AreaFills. |
One or more AreaFills are deleted. |
| DA0_0 (3) (*) |
Drafting |
Ghost link
visible in SendTo command and when opening the document. |
An object is
erroneously referencing another document. |
Deletion of
the link without behavior modification. |
No more ghost link.

|
| DA0_1 (3) (*) |
Drafting |
Ghost link
visible in SendTo command and when opening the document. |
A useless
drafting data is erroneously referencing another document. |
Deletion of
the useless drafting data and thus its links pointing others documents. |
No behavior
modification except no more ghost link when opening the document. |
| DAS_0 (1) (*) |
Generative
Drafting |
Unrelated document can be pointed by the drawing document (it appears
using Send To). Ghost Link. |
A object managing view axis origin has an invalid link to a 3D
document. |
Deletion of the invalid link. |
No more Ghost Link in Send to command. |
| DBA_0 (2) (*) |
Drafting |
Ghost link in
SentTo command. |
Bad link on a
default feature. |
Deletion of
the invalid link. |
No more
invalid links in SendTo command. |
| DCH_0 (1) |
Drafting |
Not
up-to-date driving dimension or invalid constraint between 2D and 3D. |
3D link of
constraint between 2D and 3D lost. |
Delete
constraint between 2D and 3D. |
Dimension
still not up-to-date and constraint between 2D and 3D deleted. |
| DCH_1 (2) |
Drafting |
Driving
dimension or constraint between 2D and 3D doesn't update at CATDrawing
update. |
Bad object
subscription. |
Add
subscription on dimension or constraint to 3D geometry. |
Driving
dimension or constraint between 2D and 3D updates correctly. Document
needs to be updated. |
| DCH_2 (2) (*) |
Drafting |
Sent to
command shows that an isolated view is still linked to its part (concern
views isolated before R13). |
The hybrid constraints (constraint between 2D and generated element)
of the view have not been deleted after isolate: an interactive view
should not contain hybrid constraints. |
Deletion of each hybrid constraints which can be found in an
interactive view. |
The drawing is no more linked to 3D. |
| DCR_0 (2) |
Drafting |
Not
up-to-date dimension or invalid constraint between 2D and 3D in section
view. |
An invalid
section operator is stored. |
Locate right
section operator. |
Dimension
becomes up-to-date and constraint between 2D and 3D becomes valid. Document needs to be updated. |
| DCR_1 (3) (*) |
Drafting |
Ghost link or
excessive CATDrawing data size. |
Useless
object with 3D link not deleted. |
Delete
useless object. |
Smaller
CATDrawing and no more ghost links. |
| DCR_2 (1) |
Drafting |
Broken
dimension, associative dress-up or constraint between 3D assembly
projection and interactive geometry. Or ghost link on a CATPart in Send
To command |
Information of associative dress-up (dimension, annotation,
constraint,...) for assembly positioning has been lost. |
Deletion of element. |
No more GhostLink in SendTo command.

|
| DCR_3 (1) |
Drafting |
Sent To command shows that an isolated view in a drawing is still
linked to its part. |
A link to a
3D connector has not been deleted after isolate. |
Deletion of each 3D connector which can be found in an interactive
view |
No more
GhostLink in SentTo command. |
| DCR_4 (3) |
Drafting |
A CATDrawing
document has an abnormally huge data size |
A useless object responsible of associativity still exist. |
Deletion of
useless element |
Reduce el tamaño del CATDrawing |
| DCR_5 (1) (*) |
Drafting |
The "Send to"
command shows that a drawing is linked to another drawing. The problem
disappears if constraints or dimensions on 2D element are deleted. |
A link with a
2D drafting element is pointing outside the document. |
Deletion of
this link. |
The element
which uses this link (constraint or dimension) can lose its
associativity.
Document needs to be updated. |
| DCS_1 (2) |
Drafting |
Some constraints are not taken into account (geometries can be moved
though they should be fixed). |
Constraints are not correctly aggregated in some cases and the view
solver cannot find them and take them into account. |
Change the
place where the constraints are aggregated. |
Constraints
are taken into account. Document needs to be updated. |
| DCT_0 (1) |
Drafting |
Drawing too
large in regard of what is actually useful. |
Data model
with the V4 format became useless but are nevertheless still stored. |
Delete the
useless data. |
Reduce el tamaño del CATDrawing. |
| DCT_1 (2) |
Drafting |
Bad display
of fonts, diameter symbol or not visualization of datum feature. |
An important
feature for the annotations visualization is missing. |
The visualization of the previous elements should be reestablish.
Note that it can modify visualization dimensions as well (font display
impact). |
AfterFix
Reduce the size of the model.
Document needs to be updated. |
| DCT_2 (1) (*) |
Drafting |
Ghost links
appear in SendTo command. |
There are
some features in the CATDrwCont that should have a father but that are
actually not aggregated anywhere: these corrupted/useless features are
not visualized but can have links to external documents. |
Delete the
non-aggregated feature. |
No more Ghost
Link in SendTo command. |
| DDI_0 (2) |
Drafting |
Chamfer
dimension badly positioned after update. |
Invalid
positioning data is stored. |
Positioning
data corrected. |
Chamfer
dimension moves correctly after update. |
| DDI_1 (1) (*) |
Drafting |
Ghost link on
another document from chamfer dimension. |
Chamfer
dimension has a link to an external document instead of an internal
link. |
Deletion of
Chamfer dimension. |
No more
chamfer dimension, no more ghost Link. |
| DDI_2 (1) (*) |
Drafting |
Not
up-to-date driving dimension or invalid constraint between 2D and 3D. |
Constraint
data is corrupted. |
Delete
dimension or constraint. |
No more not
up to date dimension or constraint. |
| DDI_3 (3) |
Drafting |
Dimension not
displayed but accessible from search command. |
Non
aggregated dimensions. |
Deletion of
the useless dimension. |
Document is
the same but smaller. |
| DDI_4 (2) |
Drafting |
An attribute of dimension is not valuated. |
The dimension display does not match dimension
properties. |
Update dimension properties. |
Dimension value does not go any more on the line of
dimension after view update. |
| DDI_5 (1) |
Drafting |
The number of
dimension found by the search command is higher than the number of
dimension seen by the user. After copy-paste, update or isolate,
dimensions can reappear. |
After Undo command, dimensions can disappear from the view because of
a problem of update. This problem is corrected in R15 level. |
Deletion of
each dimension which is not visualized in the view. |
Only the visualized dimensions can be found by search command. |
| DDU_0 (2) |
Drafting |
Ghost Link in
SendTo command. |
Useless data (connector, 3D feature) is erroneously
referencing another document (CATPart). |
Remove this data and thus its links pointing other
documents |
No more Ghost
Link in SendTo command. |
| DDU_1 (2) (*) |
Drafting |
Open a Drafting document displays a panel with an invalid link to
another drawing. Document has a ghost link. |
After a Copy/Paste operation, some copied dressup elements keep their
link to first drawing. |
Remove the
invalid links. |
These
dress-up elements are isolated from other CATDrawing. They are still
visualized. No more panel when opening the document. |
| DDU_2 (1) (*) |
Drafting |
A ghost link
on a CATDrawing document leads to the detection of the problem. |
A feature
(that leads to the ghost link) is set under of the DrwCont container
instead of being aggregated under a view. |
Deletion of
the axis lines, center lines or thread that are directly under the
DrwCont container. |
No more ghost
links in Send To command. |